Model:
MCS-A03

    Veterinary Anesthesia Ventilator Machine

    Main body

    High-strength engineering plastic rack, light, beautiful 
    and corrosion resistant

    Scope of application

    adult, child

    Gas source

    O2: 0.28~0.6MPa

    N2O: 0.28~0.6MPa

    Flow meter

    O2 : 0.05~1.0L/min

    1.1~10L/min

    N20: 0.05~1.0L/min

    1.1~10L/min

    O2 N2O linkage and N2O Stopper

    When using nitrous oxide, oxygen concentration>25%;

    When the oxygen pressure<0.2Kpa, the flow of nitrous 
    oxide would be  cut off.

    Flow rate of rapid 
    oxygen supply

    25~75L/min

    Low oxygen pressure alarm

    There will be sound alarm when the oxygen pressure
     < 0.2MPa

    Vaporizer

    It has the function of automatic compensation based on
     pressure, temperature, and flow rate. The regulation
     range of evaporator concentration is 0~5 vol%. Among
     Halothane, two
     can be chosen for application as required by the 
    customer. And vaporizers that are imported with original
     packaging are also available.

    Respiratory circuit 

    working mode: all-close, semi-close, semi-open 

    APL≤12.5 kPa

    Respiratory Bellows 

    bellows for adults, tidal volume range:0~1500 ml

    bellows for children, tidal volume range:0~300 ml

    anyone can be chosen for application as required by
     the customer

    Display mode

    High-definition 5.7” LCD screen display

    Part of Ventilator

    Ventilation  mode

    IPPV, SIPPV, SIMV, MANUAL

    Ventilation functions

    PEEP,SIGH, IRV

    Ventilation parameters

    Tidal volume

    50~1500 ml

    Rate

    2~99 bpm

    SIMV rate

    2~20 bpm

    I:E

    2:1~1:8

    Inspiratory trigger pressure

    -10~20 cmH2O

    PEEP                  

    2~20 cmH2O

    Pressure range           

    5~60 cmH2O

    SIGH 

    1.5 times the inspiratory time
     (60-120 adjustable)

    Security Alarm System

    Airway pressure alarm

    upper limit setting range  5~60 cmH2O

    low limit setting range     0~50 cmH2O

    Per-minute ventilation volume alarm

    upper limit setting range   1~20L/min

    low limit setting range   0~19L/min

    Tidal volume

    upper limit setting range  100~1500ml

    low limit setting range   0~1400ml

    Sustained high-pressure alarm

    it will give alarm when stress have consistently been 
    higher than 25 cmH2O

    Power

    AC 220V±10%     50Hz±1Hz(UPS, Storage battery)




get in touch with us
just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs
Related Products
One-stop medical & laboratory equipment supplier,focus on medical equipments over 10 years
Contact us

If you have a question, please contact at contact info@mecanmedical.com

+86 020 8483 5259
Copyright © 2021 Guangzhou MeCan Medical Limited  | Sitemap