0
image
image

Hospital Medical Portable Electric Syringe Pump

MCS-SP10
minimum order
1
Stock Time
3-15 working daysDay
Quantity:
Contact Now
add to cart
All Products

Hospital Medical Portable Electric Syringe Pump

Main Features
Friendliness
3 inch large LCD screen allows infusion status to be viewed easily
User friendly keypad design
Embedded handle allows for easy transportation
Intuitive programming procedure with quick guidance on screen
Safety
High accuracy: ±2%, satisfying neonatal use
Fast start, Anti-bolus, Drug name display, History record, Last therapy parameter memory
IP34 dust and water protection
Connectivity
Nurse call/ RS 232/ DC input

Specification

Dimension360 x 145 x 123mm
Syringe size5, 10, 20, 30, 50/60ml
Infusion modeRate mode, Time mode, Body weight mode
Flow rate range5ml syringe: (0.1~150)ml/h; 10ml syringe: (0.1~300)ml/h; 20ml syringe: (0.1~600)ml/h 30ml syringe: (0.1~900)ml/h; 50ml/60ml syringe: (0.1~1500)ml/h
Accumulated volume0.1~9999 ml
VTBI0.1~999.9 ml, increment is 0.1 ml; 1000-9999ml, increment is 1ml
Increment0.1~999.9 ml/h, increment is 0.1 ml/h; 1000~1500 ml/h, increment is 1 ml/h
Accuracy≤±2%
KVO rate0.1-5.0 ml/h, adjustable, increment is 0.1ml/h
Bolus rate0.10-1500ml/h
Purge rate150-800ml/h
OcclusionLow 300±125 mmHg (40kPa); Medium 525±125 mmHg (70kPa); High 900±180 mmHg (120 kPa)
Screen3 inch LCD monochrome screen, 240 x 128 pixels
TitrationYes, increment is 0.1ml/h
Keypad lockYes
PauseYes
Automatic recognition of syringe sizeYes
Self-test systemYes
Last therapy parameter memoryYes
Drug library200 drugs
History record1500 events
Weight<1.95kg (not including clamp)
HandleEmbedded handle
Mounting typeStandard: Vertical Pole
Alarm Volume1-8 levels selectable
Preset syringe brandInclude B-D Luer-Lok Tip,B.Braun OPS,Terumo SS; Local brand configuration supported
Language7, Chinese, English, Spanish, French, Russian, Turkish, Portuguese
Alarm 
 VTBI done, VTBI near done, KVO finish, syringe empty, syringe near empty, syringe not installed, syringe disengaged, occlusion, system error, system abnormal, battery low, battery empty, reminder, AC power disconnection, standby time expired
Safety Requirement 
AC power100-240V (50/60Hz, 0.4-0.14 )A
DC power10-16V (2.0-1.25A)
Battery typeLithium
Battery operation time>6 hours@5ml/h
Charging time<5 hours@100%
ClassificationCF, Class I
IP GradeIP 34
Temperature5~ 40℃for operating, -20~60℃ for storage
Humidity15~95% for operating, 10~95% for storage
Air pressure57~106kPa for operating, 50~106kPa for storage
Interface 
Data interfaceSupported, RS232
Nurse CallSupported
DC inputSupported