0
image
image
image

High Accuracy Volumetric Hospital Portable Medical Infusion Pump

MCS-IP09
minimum order
1
Stock Time
3-15 working daysDay
Quantity:
Contact Now
add to cart
All Products

High Accuracy Volumetric Hospital Portable Medical Infusion Pump

Main Features
Friendliness
Compact design with light weight
3 inch large LCD screen allows infusion status to be viewed easily
Embedded handle allows for easy transportation
Straightforward IV set installation
Intuitive programming procedure with quick guidance on screen
Safety
High accuracy: ±5%, satisfying neonatal use
Water-proof membrane on fingers preventing leakage into pump body
Anti-bolus, Drug name display, History record, Last therapy parameter memory
IP34 dust and water protection
Connectivity
Nurse call/ RS 232/ DC input

Specification

Dimension146 x 193 x 95mm
Infusion setApplicable to GB 8368-2005 disposals; diametersΦ3.5-4.5mm, thickness 0.8-1.2mm
Infusion modeRate mode, Time mode, Body weight mode, Sequential mode
Flow rate range0.1~1500ml/h
Accumulated volume0.1~9999 ml
VTBI0.1~999.9 ml, increment is 0.1 ml; 1000-9999ml, increment is 1ml
Increment0.1~999.9 ml/h, increment is 0.1 ml/h; 1000~1500 ml/h, increment is 1 ml/h
Accuracy≤ ±5%
KVO rate0.1-5.0 ml/h, adjustable, increment is 0.1ml/h
Bolus rate0.10-1500ml/h
Purge rate800ml/h
OcclusionLow 150±125 mmHg (20kPa); Medium 525±125 mmHg (70kPa); High 900±180 mmHg (120 kPa)
Air bubble detectionSingle bubble detection: 50, 100, 250, 500, 800l μl Accumulated bubble detection: 0.1-4.0ml/h, adjustable
Screen3.0' LCD monochrome screen, 240 x 128 pixels
TitrationYes, increment is 0.1ml/h
Keypad lockYes
PauseYes
Self-test systemYes
Last therapy parameter memoryYes
Drug library200 drugs
History record1500 events
Weight<1.6kg (not including clamp)
HandleEmbedded handle
Mounting typeStandard: Vertical Pole
Alarm Volume1-8 levels selectable
Language8, Chinese, English, Spanish, French, Russian, Turkish, Portuguese, German
Alarm
VTBI done, VTBI near done, KVO finish, Bottle empty, door open, IV set not installed, occlusion, air in line, drop error, system error, system abnormal, battery low, battery empty, reminder, AC power disconnection, standby end
Safety Requirement
AC power100-240V (50/60Hz, 0.4-0.14 A)
DC power10-16V (2.25-1.5A)
Battery typeLithium
Battery operation time>4 hours@25ml/h
Charging time≤6 hours@100%
ClassificationCF, Class I
IP GradeIP 34
Temperature5~640ºC for operating, -20~60ºC for storage
Humidity15~95% for operating, 10~95% for storage
Air pressure57~106kPa for operating, 50~106kPa for storage
Interface
Data interfaceSupported, RS232
Nurse CallSupported
DC inputSupported