High-strength Anesthesia Machine with Ventilator
High-strength Anesthesia Machine with Ventilator
AnesthesiaMachine
Main body | High-strength engineering plastic rack. light, beautiful and corrosion resistant |
Scope of application | adult, Child |
Gas source | O2: 0.28-0.6MPa N2O: 0.28-0.6MPa |
Rapid oxygen flow | O2:0.1-1.0L/min 1.1-10L/min N2O: 0.1-1.0L/min 1.1-10L/min |
O2, N2O linkage and N2O Stopper | When using nitrous oxide, oxygen concentration>25%; When the oxygen pressure<0.2MPa. the flow of nitrous oxide would be cut off. |
Flow rate d rapid oxygen supply | 25-75L/min |
Vaporizer | it has the function of automatic compensation based on pressure, temperature, and flow rate. The regulation range of evaporator concentration is 0~5vol%. Among Halothane, Enflurane, Isoflurane and Sevoflurane, two can be chosen for application as required by the customer. And vaporizers that are imported with original packaging are also available. |
Low oxygen pressure alarm | There will be sound alarm when the oxygen pressure < 0.2MPa |
Respiratory circuit | work mode: all close, semi-close, semi open APL: ≤12.5kPa |
Respiratory Bellows | bellows for adults, bellows for children tidal volume range:0~1500ml |
Ventilator
Display mode | High-definition 5.7' LCD screen display | |
Ventilation mode | IPPV, SIPPV, SIMV, MANUAL | |
Ventilation function | PEEP, SIGH, IRV | |
Ventilation parameters | ||
Tidal volume | 50-1500ml | |
Rate | 2-99bpm | |
SIMV rate | 2-20bpm | |
I:E | 2:1-1:8 | |
Inspiratory trigger pressure | -10~20cmH2O | |
PEEP | 02~20cmH2O | |
Pressure range | 10~60cmH2O | |
SIGH | 1.5 times the inspiratory time/100bpm | |
Parameter for ventilation monitoring | tidal volume. Minute Ventilation volume. IPPV rate. SIMV rate. total respiratory rate. I/E. peak pressure of airway. pressure -time waveform. flow rate -fire waveform. PEEP. inspiratory trigger pressure.( average pressure, oxygen concentration. battery capacity) | |
Security Alert System | ||
Oxygen concentration alarm | upper limit setting range low limit setting range | (50%-99%) (15%-80%) |
Airway pressure alarm | upper limit setting range low limit setting range | 5-60cmH2O 0-50cmH2O |
minule ventlation volume alarm | upper limit setting range low limit setting range | 1-30L/min 0-29L/min |
tidal volume | upper limit setting range low limit setting range | 10-2000ml 0-1800ml |
sustained high-pressure alarm | it will give alarm when stress have consistently been higher than 25cmH2O | |
(Suffocation alarm, Power alarm, Intubation off alarm, battery voltage alarm) | ||
Power | AC 100-240V 50/60Hz(UPS. Storage battery) | |
(Mechanical Arms) | ||
(End-tidal CO2 monitoring) | ||
(Specific interface of waste anesthesia gas) Items within brackets are optional. | ||