0
image
image

Medical Education Model Half Body Manikin For CPR Training

MCE-ET10
minimum order
1
Stock Time
3-15 working daysDay
Quantity:
Contact Now
add to cart
All Products

Medical Education Model Half Body Manikin For CPR Training

MCE-ET10

Medical Education Model Half Body Manikin For CPR Training 3

Features
1. Simulating standard open airway
2. External breast compression: display device and alarm device
a) Indicator light display of correct and wrong compression ; alarm of wrong compression;
b) Intensity display of correct (at least 5cm) and wrong (less than 5cm) compression; alarm of wrong compression.
3. Artificial respiration (inhalation): display device and alarm device
a) Inhalation <500-600ml or=""> 600ml, wrong indicator light display and alarm prompting; inhalation between 500-600ml right indicator light display;
b) Indicator light display open airway;
c) Inhalation too quickly or too much result in air entering into stomach; indicator light display and alarm prompting.
4. Ratio of compression and artificial respiration: 30:2 (one or two person).
5. Operating cycle: one cycle includes five times of 30:2 ratio of compression and artificial respiration. 
6. Operation frequency: at least 100 times per minute
7. Operation methods: exercise operation
8. Examination of pupil response: mydriasis and myosis
9. Examination of carotid response: pinch the pressure ball by hand and simulate carotid pulse
10. Working conditions: Input power is 110-240V

Optional function
1. Endotracheal intubation
2. Gastrolavage

Packing size80*30*40cm
G.W13KGS


MCE-ET11

Medical Education Model Half Body Manikin For CPR Training 4

Features
1. Simulating standard open airway
2. External breast compression: display device and alarm device;
a) Indicator light display of correct and wrong compression; alarm of wrong compression;
b) Intensity display of correct (at least 5cm) and wrong (less than 5cm) compression; alarm of wrong compression.
3. Artificial respiration (inhalation): display device and alarm device;
a) Inhalation <500ml or=""> 600ml, wrong indicator light display and alarm prompting; Inhalation between 500-600ml right indicator light display;
b) Ratio of compression and artificial respiration: 30:2 (one or two person).
4. Operating cycle: one cycle includes five times of 30:2 ratio of compression and artificial respiration
5. Operation frequency: at least 100 times per minute 
6. Operation methods: exercise operation
7. Examination of pupil response: mydriasis and myosis
8. Working conditions: Input power is 110-240V

PACKAGE SIZE: 80*30*40cm
G.W.: 13KGS


MCE-ET12

Medical Education Model Half Body Manikin For CPR Training 5

Features
1. Simulate standard open airway
2. External breast compression, intensity display of correct (at least 5cm)
1) The yellow indicator light display of correct compression position
2) Buzzing sound of correct compression intensity, the green indicator light display
3) Alarming sound of wrong compression intensity, the red indicator light display
3. Artificial respiration (inhalation): the volume of inhalation is observed through observing the wave of breast;
4. Operation methods: exercise operation
5. Power supply: battery

PACKAGE SIZE: 80*30*40cm
G.W.: 13KGS