ICU Electric Anesthesia Medical Ventilator Machine

Model: MCS-V09
Description:
MOQ: 1 set
Lead time: 3-15 working days
Payment: T/T in advance,Western Union,L/C,MoneyGram,Cash

Quantity:

Add to cart Get price

    ICU Electric Anesthesia Medical Ventilator Machine

    The MCB-PA-700B ventilator is gas driven by medical compressed oxygen and compressed air. In the inspiratory phase, two streams of compressed gas (compressed oxygen and compressed air) flow into a high performance air-oxygen mixer to form a mix of oxygen and air with a certain pressure.
    Main Features
    Display: 10.4''LCD Display Following Parameters & Real time waveform display
    1.Operating mode and respiratory rate;
    2.Ventilator control frequency set by medical staff;
    3.Tidal volume of each breath in the patient;
    4.Occurrence of spontaneous breath in the patient and spontaneous breathing frequency;
    5.Expiratory phase and inspiratory phase and actual respiratory rate;
    6.Minute volume;
    7.Setting and adjustment of inspiration triggering pressure, PEEP, and highest airway pressure;
    8.Real-time variation in internal airway pressure.
    Ventilator Construction
    1.Environmental Protection Material construction, hardly to be broken.
    2.Trolly: Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions.
    Air Compressor
    1.Power: AC220V + 22 v, 50 Hz + 1 Hz and 300 va has a good reserve of single-phase ac power supply
    2.FUSE :Φ 5 x 20 / F8A
    3.Output gas pressure: 0.3 ~ 0.4 MPa
    4.Output gas minimum flow: ≥50L/Min
    5.Output gas transient flow: ≥100L/Min


    Physical specifications 
    Display 10.4'' LCD Display
    Mode pneumatically powered and electrically controlled system
    Trolley Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
    Technical Specifications
    Gas requirement Medical oxygen and nitrous oxide with a pressure ranging from 280~600kpa
    safety valve  <12.5 kPa
    Respiratory Rate 1 ~ 99 bpm
    Oxygen Concentration 21% ~ 100%  
    Maximum Minute ventilation ≥18L / min
    modes of ventilation A/C, IPPV, SIPPV, IMV, SIMV, PEET. MANUAL, SIGH, SPONT
    Ventilator compliance ≤30 Ml/kPa
    PEEP 0 ~ 1.0 kPa
    Ptr -10 ~ 10 hPa
    IMV frequency 1~20 bpm
    I/E Ratio 4:1~1:4, Has the inverse ratio ventilation
    Tidal Volume Setting Range:  50~1500ML   Display Range: 0~2000ml ;  resolution ratio: 10ml
    Inspiratory Plateau 0~1s
    Maximum Safety  Pressure ≤ 6.0kPa
    Sigh one deep breath per 80 controlled respirations, the inspiration time is 1.5 times of the setting point
    Pressure limit range 1.0~ 6.0kPa
    Airway pressure alarm: Audible and visual and with yellow and red color indicating Lower: 0.1 kPa ~ 6.0 kPa;   Upper: 0 ~ 5.0  kPa
    ±0.2 kPa
    Ventilation Volume alarm:  ≥ 18L/ MIN 
    Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately
    Alarm Time: keep >120s
    The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
    Operating conditions
    Ambient temperature:  10 ~ 40oC
    Relative humidity: no higher than 80 %
    Atmospheric pressure: 860 hPa ~ 1060 hPa
    Power requirement:  100-120 Vac, 50/60 Hz;  
    Attention: the AC power supply used for the anesthesia machine must be well   grounded.
    Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. 
    Storage
    Ambient temperature -15℃~ +50℃
    Relative humidity no higher than 95 %
    Atmospheric pressure 86 kPa ~ 106 kPa.
      It should be stored in a room without corrosive gas and well ventilated
    Package
    packaging box comply with the requirement of GB/T 15464
      Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
      Moisture protection and rain protection to ensure that product is protected from natural damage. 
    Safety & Alarm
    Gas source pressure Immediate alarm; “high level alarm” indicator flickers raising an audible alarm.
    Airway Pressure Alarm The airway pressure exceeds 15hpa. The maximum delay is no longer than 17s. The “high level alarm” indicator flickers raising an audible alarm. 
    Tidal Volume Alarm Lower than 50ml, The alarm will be raised after one breathing cycle. 
    Ventilation Volume Alarm Lower: 0~12L/Min;   Up: 18L/ Min
    Battery Voltage Alarm It alrms when the battery voltage is lower than 10.5V.
    Power On Self Test Self test before working, assure it's working normally. 