Medical Center Mobile Anesthesia Workstation

Model: MCS-A19
Description:
MOQ: 1 set
Lead time: 3-15 working days
Payment: T/T in advance,Western Union,L/C,MoneyGram,Cash

Quantity:

Add to cart Get price

    Medical Center Mobile Anesthesia Workstation

    Main Features
    1. Applied for closed, semi-closed, semi-open inhalation anesthesia, controlled or assisted ventilation, monitoring and display patients’ ventilation parameters
    2. Applied for adult and pediatric
    3. Integrated anesthetic ventilation system, APL security air relief valve is available
    4. Vaporizers: Advanced temperature, flow and pressure compensation technology, Isofurane, Enfurance, Halothane and Sevoflurance as per option
    5. 8.4” TFT-LCD display screen

    Specification

    Type: Electronically controlled, Pneumatic driven

    Patient spectrum: Pediatric to bariatric

    Mode of ventilation: VCN, SIGH, SIMV, Stand-by, Manual, PEEP(Optional)

    Hypoxic guard system: N2O cut-off valve, O2 concentration no less than 25%

    Safety valve: <12.5kpa


    Monitoring: VT, MV, BPM, Paw, FiO2, Lung compliance

    Waveform: Pressure-time, flow-time, pressure-volume loop, volume-time (Optional), flow-volume loop (Optional)

    Power: AC 220V±10%, 50Hz±2%, built-in battery support

    Gas: O2, N2O, air (Optional)


    Alarm: Optimal multi-class alarm unit, VT beyond limitation, upper and lower limitation of ventilation, upper  and lower limitation of ventilation, upper and lower limitation of airway pressure, asphyxiation, current failure, gas source hypotonic, gas circuit abnormity, upper and lower limitation of CO2 concentration (Optional)

    Prompt and protection: Prompt for parameter limitations, protection for unreasonable parameter setting.