anesthesia machine anesthesia machine
anestesia machine anestesia machine
china anesthesia machine china anesthesia machine
anesthesia machine with ventilator anesthesia machine with ventilator
advanced anesthesia machine advanced anesthesia machine
anesthesiology machine anesthesiology machine

Medical Anestesia Equipment, Anesthesia Machine For Anesthesiology Department

Model: MCS-A16
Description: Our Anesthesia Machine is equipped with an accurate dedicated anaesthetic vaporizer and a safety device for preventing cyanosis and necessary alarm system.It has color LCD screen,can display time pressure, flow time and pressure-volume loop, with oxygen concentration monitoring.This anestesia machine is suitable for low flow anesthesia.
MOQ: 1 set
Lead time: 3-15 working days
Payment: T/T in advance,Western Union,L/C,MoneyGram,Cash

Quantity:

Add to cart Get price

    Medical Anestesia Equipment, Anesthesia Machine For Anesthesiology Department

    Prospective service and support

    Our Anesthesia Machine is equipped with an accurate dedicated anaesthetic vaporizer and a safety device for preventing cyanosis and necessary alarm system. During the anesthesia, the patient’s respiratory functions can be managed by using a microcomputer controlled pneumatic electrically controlled synchronizing anesthesia respirator. Each connection part of the whole machine is a standard interface. A highly efficient and large volume soda lime absorber can minimize the re-inhalation of carbon dioxide by the patient.

    Power On Self Test

    The automatic conversion for standby power while AC power outage,  keep working  not less than 1 hour.

    Component Details

    Na Lime Tank: Equipped with international advanced one-piece soda lime cans,it can be fast replaced with  hands  and  withstand temperatures up to 134℃

    Circuit: Metal integrated breathing circuit, Perfect function of gas sealing under high temperature disinfection, and easy to cleaning and disinfected.

    Flowmeter: 5-Tubes flowmeter;

    1. Assure that O2 output not lower than 20%

    2. NO2 automatically off while O2deficiency

    Display & Operating  Interface

    10.4'' LCD Display Screen, can feedback patient data

    Shuttle button: More accurate

    Vaporizers:  En flurane/ Iso flurane/ Sevo flurane(Option: Halothane)  

    Setting Range:  0.5~5%


    china anesthesia machine



    1.Manual/Maneuvering changeover valve

    2.Common gas inlet

    3.Gas storage bag connection port

    4.Carbon dioxide absorber

    5.Exhalation valve

    6.Exhalation screwed pipe port

    7.Inhalation screwed pipe port

    8.Inhalation valve

    9.Pressure gauge

    10.APL safety valve

    11.Air bellow

    12.Driving gas inlet

    13.Pressure signal  

    14.Oxygen concentration sensor interface

    15.Waste gas exhaust port

    16.Connection with 17 through screwed pipe

    17.Connection with 16 through screwed pipe


    Physical specifications 
    Screen 10.4 '  LCD  Display Screen
    Suitable Adult & Child
    Mode pneumatically powered and electrically controlled system
    Working Mode Closed; Semi-Closed; Semi-Open
    Circuit Breathing circuit integrated standards
    Flowmeters 5 Tubes Flowmeters:  O2:0.1~10L/Min,  N2O:0.1~10L/Min; Air: 0.1~10L / Min
    Trolley Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions
    Drawer unit TWO drawers  totally extractable
    Technical Specifications
    Gas requirement Medical oxygen and nitrous oxide with a pressure ranging from O2: 0.32~0.6MPa ;   NO2: 0.32 MPa to 0.6 MPa.
    safety valve  <12.5  kPa
    Respiratory Rate 1~99bpm
    oxygen concentration in the mixed gas N2O/O > 21%
    Oxygen Flush 25~75 L/min
    modes of ventilation A/C, IPPV, SIPPV, IMV, SIMV, PCV, VCV, PEEP, MANUAL, SIGH
    PEEP: 0 ~ 2.0 kPa
    Inspiratory trigger pressure -1.0kPa ~ 2.0 kPa
    I/E Ratio 8:1 ~ 1:10, Has the inverse ratio ventilation
    Tidal Volume 0 ~ 1500 ML
    Inspiratory Plateau 0~1s
    O2 Concentration 21%~100%
    Sigh one deep breath per 70 ~ 120 controlled respirations, the inspiration time is 1.5 times of the setting point
    Maximum safety pressure ≤ 12.5 kPa
    Pressure limit range 0 ~ 6.0  kPa
    Airway pressure alarm: Audible and visual and with yellow and red color indicating Lower: 0.2kPa~5.0kPa;   Upper: 0.3~6.0  kPa
    ±0.2 kPa
    Tidal volume alarm: Audible and visual and with yellow and red color indicating upper alarm: 50 to 2000ml, lower alarm: 0~1800ml
    Oxygen concentration alarm: Audible and visual and with yellow and red color indicating upper alarm: 21% ~100%;  lower alarm:10%~80%
    Power Supply Alarm Ac/dc power supply are after failing to send out alarm immediately
    Alarm Time: keep >120s
    The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator.
    Operating conditions
    Ambient temperature 10 ~ 40oC
    Relative humidity no higher than 80 %
    Atmospheric pressure 860 hPa ~ 1060 hPa
    Power requirement 100-120 Vac, 50/60 Hz;  
    Attention: the AC power supply used for the anesthesia machine must be well grounded.
    Attention: the anesthesia machine used must be equipped with a carbon dioxide monitor complying with ISO 9918:1993, an oxygen monitor complying with ISO 7767:1997 and an expiratory gas volume monitor complying with 51.101.4.2 of Medical Electrical Equipment Part II: Special Requirements for Safety and Basic Performance of Anesthesia System. 
    Storage
    Ambient temperature -15oC ~ +50oC
    Relative humidity no higher than 95 %
    Atmospheric pressure 86 kPa ~ 106 kPa.
    It should be stored in a room without corrosive gas and well ventilated
    Package
    packaging box comply with the requirement of GB/T 15464
    Between the packaging box and product, soft material with appropriate thickness provided to prevent loosening and mutual friction during transportation
    Moisture protection and rain protection to ensure that product is protected from natural damage. 
    Safty & Alarm
    Oxygen Alarm It alarms when the oxygen  supply from pipe or cylinders lower than 0.2MPa
    Ventilation Volume Alarm Lower: 0~12L/Min;   Up: 18L/ Min
    Power Alarm It Alrmas while AC and DC supply failure ; Keep alraming  time: >120s
    Air Tract Pressure Alarm Lower: 0.2kPa ~5.0 kPa;  Up: 0.3kPa ~ 6.0kPa


    Q:What is the packing size of the anesthesia machine?

    A:2 cartons:940*790*1270mm,700*680*370mm,Gross weight:114KG.


    Q:What is the packing list of the anestesia machine?

    A

    No NAME COUNT UNITS
    1 Main unit 1 pc
    2 5-tube flow meter 1 pc
    3 Patient circuit(Na lime tank) 1 set
    4 bellows 1 set
    5 vaporizer 2 pcs
    6 Oxygen transport pipe 1 pc
    7 Oxygen concentration probe  1 pc
    8 air transport pipe 1 pc
    9 Flowmeter sensor 1 set
    10 Oxygen pressure reducer 1 set
    11 anaesthetic reservoir bag ( Blue) 2 pc
    12 Threaded pipe 4 pc
    13 Mask (Silicom) 2 pc
    14 Y pipe 1 pc
    15 Battery 1 pc
    16 Power wire 1 pc
    17 Tools Attachment 1 set
    18 Tail gas absorber  2 pcs
    19 User Manual (English Version) 1 pc
    20 Patient Monitor(option) 1 pc