Category:

    Contact us

    Andy Miao

    Tel: +86 20 8483 5259

    Whatsapp: +86 159 8923 0468

    Email: info@mecanmedical.com


    Customer visit

    Customer visit

    Medical Philippines Expo 2018

    Medical Philippines Expo 2018

    Medical Philippines Expo 2018

    Medical Philippines Expo 2018

    MEDIC EAST AFRICA 2018

    MEDIC EAST AFRICA 2018

    MEDIC EAST AFRICA 2018



    Customer feedback

    customer feedback

Infant Warmer Infant Warmer
Infant Radiant Warmer Infant Radiant Warmer
Phototherapy Baby Warmer Phototherapy Baby Warmer
Infant Warmer Infant Warmer
Infant Radiant Warmer Infant Radiant Warmer
Phototherapy Baby Warmer Phototherapy Baby Warmer

Infant Warmer, Infant Radiant Warmer With Phototherapy Baby Warmer

Model: MC-IRW93B
Description:
MOQ: 1 set
Lead time: 3
Payment: T/T in advance, Western Union, L/C, MoneyGram, Cash

Quantity:

Add to cart Get price

    Infant Warmer, Infant Radiant Warmer With Phototherapy Baby Warmer

    What is the detail of our infant radiant warmer?
    Specification
    Three control modes: Pre-warm mode, manual mode
    and baby mode controlled by micro-computer;
    Set temperature and baby temperature can be displayed separately;
    Tri-safety over-temp protection:
    Double CPU control system.
    Isolated over heating cutoff device.
    Horizon angle of heater head and inclination of the bassinet can be adjusted;
    The glass panels around bassinet can be disassemble or turned outward;
    X-ray cassette under the bassinet;
    With temperature data storage function
    APGAR timer
    RS-232 connector
    Neonate phototherapy equipment
    Optional configuration: Vertical height adjustment stand
    Mode of control: Pre-warm mode control, manual mode control and baby mode controlled by micro-computer.
    Baby mode temperature control range:34.5~ 37.5℃
    Temperature sensor display range: 5℃~65℃
    Accuracy of skin temperature sensor: ≤0.3℃
    Deviation between the measure by the skin temperature sensor
    and control temperature: ≤0.5℃
    Temperature uniformity of mattress: ≤2℃
    Angle of warmer module: 0°,30°,60°for two ways
    Inclination of the bassinet: ±10°
    APGAR timer: it will give sound when the unit tones at 1’,5’,10’
    Failure alarm: over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
    Max.Bilirubin uniformity of radiating on the mattress effective range: >=1000uW/cm2
    Bilirubin niformity of radiating on the mattress effective range:>0.4
    Wave length of blue light: 420-470nm.
    More infant radiant warmers for your referenceInfant WarmerInfant WarmerInfant WarmerInfant WarmerInfant Warmer