CTG Portable Fetal Monitor, Twin Fetal Monitor

Model: MC-9000E
Description:
MOQ: 1 set
Lead time: 3-15 working days
Payment: T/T in advance, Western Union, L/C, MoneyGram, Cash

Quantity:

Add to cart Get price

    CTG Portable Fetal Monitor, Twin Fetal Monitor

    What is the detail of our CTG / Fetal Monitor ?
    Compact and lightweight design
    7" color TFT screen, folding 90 degrees
    Built-in high dot matrix thermal printer with long life
    A standard patient event marker and a clinical event marking button to mark clinical events separately. 
    Auto fetal movement are available.
    Multi-crystals, wide beam forming, high sensitivity ultrasound transducer, low ultrasound power
    AC or Li-ion battery
    More than 12 hours data storage, which can be recalled and reprinted.
    Technical Specifications
    Fetal Heart Rate: Multi-crystal,pulsed doppler,high sensitive
    Transducer Strengh: <5mW/cm2 
    Working frequency: 1.0MHz
    Signal processing special DSP system and mode recognization 
    Measurement range: 50~210 bpm
    Alarm Range: High: 160 170 180 190 bpm
                             Low : 90 100 110 120 bpm
    The largest audio output power: 1.5W
    TOCO
    Measurement range 0~100units
    Battery working time: 2 hours(no printer working) 
    Speaker: 1W
    Power Supply AC 220V±20%,50Hz or 8.4V Li-battery 
    Power consumption: <20W
    Working Environment Temperature: 10~40 ℃, RH: 10~80%
    Transducer Acoustic Output Under the requirements laid down in IEC 1157, 1992, the peak negative acoustic pressure does not exceed 1Mpa. The output beam intensity does not exceed 20mW/cm2 and the spatial-peak temporal-ave rage intensity does not exceed 100mW/cm2
    Dimension 295W×240D×73H×mm
    Net weight 1.75kg
    Standard: FHR, TOCO, FM
    Optional: Twins,FAS(Fetal acoustic simulator)